USGS National-Strong Motion Program |
|
Preliminary
Corrected Peak Ground Acceleration and Velocity and Pseudo-Spectral
Acceleration Values for |
|
May 18, 2009,
Lennox, California Earthquake (posted 05/22/2009) |
|
|
|
|
|
|
Mw 4.7,
05/18/2009, 03:39 UTC, 05/17/2009, 08:39 PM PDT, 33.937 N, 118.345 W, 15.1 km
depth, Regional Network ID# ci10410337 |
|
Sta |
Inst |
Inst |
State: City; Recorder Location |
Owner |
Lat |
Lon |
Dist |
Az |
Ch |
Sensor |
Orient |
PGA |
PGV |
PSA at: |
|
Code |
type |
S/N |
|
|
deg |
deg |
km |
deg |
No |
type |
deg |
cm/s/s |
cm/s |
0.3 s |
1.0 s |
3.0 s |
|
5243 |
K2 |
579 |
CA:Hawthorne;FAA Bldg |
USGS |
33.8954 |
-118.3768 |
5.5 |
212 |
1 |
FBA-2g |
360 |
-137 |
6.07 |
14.3 |
4.02 |
0.402 |
|
|
|
|
|
|
|
|
|
|
2 |
FBA-2g |
UP |
53 |
0.99 |
2.9 |
0.42 |
0.054 |
|
|
|
|
|
|
|
|
|
|
3 |
FBA-2g |
90 |
-119 |
-5.64 |
15.3 |
3.23 |
0.212 |
|
5429 |
Etna |
2590 |
CA:Compton;Cressey
Park FS 3 |
USGS |
33.9040 |
-118.2455 |
9.9 |
112 |
1 |
EpiSen |
90 |
-157 |
-6.16 |
25.8 |
3.49 |
0.333 |
|
|
|
|
|
|
|
|
|
|
2 |
EpiSen |
360 |
-207 |
6.84 |
38.0 |
2.53 |
0.183 |
|
|
|
|
|
|
|
|
|
|
3 |
EpiSen |
UP |
40 |
0.80 |
3.6 |
0.33 |
0.026 |
|
5411 |
K2 |
606 |
CA:Torrance;Fire
Station 1 |
USGS |
33.8307 |
-118.3289 |
11.9 |
173 |
1 |
FBA-2g |
360 |
108 |
4.03 |
15.5 |
1.76 |
0.163 |
|
|
|
|
|
|
|
|
|
|
2 |
FBA-2g |
UP |
47 |
-0.90 |
3.8 |
0.53 |
0.050 |
|
|
|
|
|
|
|
|
|
|
3 |
FBA-2g |
90 |
-160 |
7.30 |
36.3 |
1.98 |
0.186 |
|
5477 |
K2 |
2508 |
CA:LA;300 N Los
Angeles Federal Bldg |
USGS |
34.0537 |
-118.2397 |
16.2 |
37 |
|
|
|
|
|
|
|
|
|
|
|
|
2nd Floor, S side W
corridor |
|
|
|
|
|
1 |
EpiSen |
128 |
16.7 |
-0.55 |
1.6 |
0.48 |
0.074 |
|
|
|
|
2nd Floor, S side W
corridor |
|
|
|
|
|
2 |
EpiSen |
38 |
10.7 |
0.59 |
1.4 |
0.53 |
0.088 |
|
|
|
|
2nd Floor, N side W
corridor |
|
|
|
|
|
3 |
EpiSen |
128 |
12.3 |
0.56 |
1.5 |
0.48 |
0.070 |
|
|
|
|
Basement, S side W
corridor |
|
|
|
|
|
4 |
EpiSen |
128 |
12.6 |
-0.45 |
1.2 |
0.52 |
0.052 |
|
|
|
|
Basement, S side W
corridor |
|
|
|
|
|
5 |
EpiSen |
38 |
10.3 |
0.64 |
1.8 |
0.59 |
0.080 |
|
|
|
|
Sub-basement, NW end
(inoperative) |
|
|
|
|
|
6 |
EpiSen |
128 |
|
|
|
|
|
|
|
|
|
1st Floor, SW corner |
|
|
|
|
|
7 |
EpiSen |
128 |
-17.7 |
-0.59 |
1.8 |
0.55 |
0.054 |
|
|
|
|
1st Floor, SW corner |
|
|
|
|
|
8 |
EpiSen |
38 |
14.7 |
0.72 |
2.0 |
0.59 |
0.080 |
|
|
|
|
1st Floor, N end |
|
|
|
|
|
9 |
EpiSen |
128 |
9.6 |
-0.49 |
1.5 |
0.49 |
0.051 |
|
|
|
|
Sub-basement, S end |
|
|
|
|
|
10 |
EpiSen |
128 |
-13.2 |
-0.49 |
1.3 |
0.54 |
0.055 |
|
|
|
|
Sub-basement, S end |
|
|
|
|
|
11 |
EpiSen |
38 |
-8.4 |
0.59 |
1.7 |
0.59 |
0.080 |
|
|
|
|
Sub-basement, S end |
|
|
|
|
|
12 |
EpiSen |
UP |
5.6 |
0.12 |
0.5 |
0.13 |
0.025 |
|
5477 |
K2 |
2509 |
CA:LA;300 N Los
Angeles Federal Bldg |
USGS |
34.0537 |
-118.2397 |
16.2 |
37 |
|
|
|
|
|
|
|
|
|
|
|
|
5th Floor, S side W
corridor |
|
|
|
|
|
1 |
EpiSen |
38 |
-7.4 |
0.65 |
1.5 |
0.47 |
0.164 |
|
|
|
|
5th Floor, S side W
corridor |
|
|
|
|
|
2 |
EpiSen |
128 |
8.4 |
0.73 |
1.7 |
0.43 |
0.113 |
|
|
|
|
5th Floor, N side W
corridor |
|
|
|
|
|
3 |
EpiSen |
128 |
10.7 |
0.72 |
1.7 |
0.42 |
0.109 |
|
|
|
|
8th Floor, S side W
corridor |
|
|
|
|
|
4 |
EpiSen |
38 |
7.5 |
-1.09 |
1.2 |
1.13 |
0.236 |
|
|
|
|
8th Floor, S side W
corridor |
|
|
|
|
|
5 |
EpiSen |
128 |
8.8 |
-0.96 |
1.6 |
0.93 |
0.154 |
|
|
|
|
8th Floor, N side W
corridor |
|
|
|
|
|
6 |
EpiSen |
128 |
-7.4 |
-0.83 |
1.4 |
0.90 |
0.154 |
|
|
|
|
Penthouse, center W
side |
|
|
|
|
|
7 |
EpiSen |
128 |
8.7 |
-1.15 |
1.7 |
1.13 |
0.170 |
|
|
|
|
Penthouse, N end W
side |
|
|
|
|
|
8 |
EpiSen |
128 |
-9.8 |
1.03 |
1.9 |
1.08 |
0.167 |
|
|
|
|
no sensor |
|
|
|
|
|
9 |
|
|
|
|
|
|
|
|
|
|
|
Penthouse, S end W
side |
|
|
|
|
|
10 |
EpiSen |
38 |
8.1 |
-1.30 |
1.4 |
1.31 |
0.254 |
|
|
|
|
Penthouse, S end W
side |
|
|
|
|
|
11 |
EpiSen |
128 |
9.3 |
-1.06 |
1.9 |
1.14 |
0.170 |
|
5449 |
K2 |
2437 |
CA:Santa Ana; Federal
Bldg |
USGS |
33.7486 |
-117.8750 |
48.3 |
116 |
|
|
|
|
|
|
|
|
|
|
|
|
Basement floor, south |
|
|
|
|
|
1 |
EpiSen |
90 |
11.9 |
-0.83 |
2.8 |
0.83 |
0.057 |
|
|
|
|
Basement floor, south |
|
|
|
|
|
2 |
EpiSen |
360 |
-10.8 |
-0.99 |
3.6 |
0.62 |
0.061 |
|
|
|
|
Basement floor, south |
|
|
|
|
|
3 |
EpiSen |
UP |
-5.2 |
0.21 |
1.4 |
0.26 |
0.016 |
|
|
|
|
Basement ceiling,
west |
|
|
|
|
|
4 |
EpiSen |
360 |
12.0 |
-1.04 |
3.9 |
0.60 |
0.061 |
|
|
|
|
1st floor ceiling,
west |
|
|
|
|
|
5 |
EpiSen |
360 |
13.9 |
-1.03 |
3.5 |
0.55 |
0.062 |
|
|
|
|
3rd floor ceiling,
west |
|
|
|
|
|
6 |
EpiSen |
360 |
-17.5 |
-1.33 |
6.0 |
0.59 |
0.075 |
|
|
|
|
Basement ceiling,
east |
|
|
|
|
|
7 |
EpiSen |
360 |
-13.8 |
-1.14 |
4.6 |
0.61 |
0.063 |
|
|
|
|
Basement ceiling,
east (bad sensor) |
|
|
|
|
|
8 |
EpiSen |
90 |
|
|
|
|
|
|
|
|
|
1st floor ceiling,
east |
|
|
|
|
|
9 |
EpiSen |
360 |
17.2 |
-1.28 |
5.8 |
0.60 |
0.069 |
|
|
|
|
1st floor ceiling,
east |
|
|
|
|
|
10 |
EpiSen |
90 |
-23.1 |
-1.44 |
6.4 |
0.82 |
0.068 |
|
|
|
|
3rd floor ceiling,
east |
|
|
|
|
|
11 |
EpiSen |
360 |
-27.1 |
1.56 |
8.9 |
0.82 |
0.091 |
|
|
|
|
3rd floor ceiling,
east |
|
|
|
|
|
12 |
EpiSen |
90 |
32.0 |
-2.07 |
10.3 |
1.89 |
0.123 |
|
5449 |
K2 |
2438 |
CA:Santa Ana; Federal
Bldg |
USGS |
33.7486 |
-117.8750 |
48.3 |
116 |
|
|
|
|
|
|
|
|
|
|
|
|
5th floor ceiling,
west |
|
|
|
|
|
1 |
EpiSen |
360 |
-17.4 |
1.26 |
6.9 |
1.35 |
0.089 |
|
|
|
|
7th floor ceiling,
west |
|
|
|
|
|
2 |
EpiSen |
360 |
-8.0 |
0.90 |
1.5 |
2.17 |
0.102 |
|
|
|
|
8th floor ceiling,
west |
|
|
|
|
|
3 |
EpiSen |
360 |
-14.2 |
1.52 |
4.4 |
2.45 |
0.108 |
|
|
|
|
5th floor ceiling,
east |
|
|
|
|
|
4 |
EpiSen |
360 |
24.2 |
1.36 |
8.9 |
1.50 |
0.107 |
|
|
|
|
5th floor ceiling,
east |
|
|
|
|
|
5 |
EpiSen |
90 |
23.2 |
-1.87 |
8.4 |
3.56 |
0.165 |
|
|
|
|
9th floor ceiling,
west |
|
|
|
|
|
6 |
EpiSen |
360 |
-23.4 |
2.07 |
7.8 |
2.78 |
0.124 |
|
|
|
|
7th floor ceiling,
east |
|
|
|
|
|
7 |
EpiSen |
360 |
-9.8 |
1.13 |
2.2 |
2.21 |
0.104 |
|
|
|
|
7th floor ceiling,
east |
|
|
|
|
|
8 |
EpiSen |
90 |
18.9 |
-2.02 |
2.6 |
4.97 |
0.183 |
|
|
|
|
8th floor ceiling,
east |
|
|
|
|
|
9 |
EpiSen |
360 |
19.9 |
1.90 |
5.6 |
2.55 |
0.114 |
|
|
|
|
8th floor ceiling,
east |
|
|
|
|
|
10 |
EpiSen |
90 |
25.2 |
-2.95 |
6.9 |
5.50 |
0.193 |
|
|
|
|
9th floor ceiling,
east |
|
|
|
|
|
11 |
EpiSen |
360 |
31.7 |
2.60 |
9.6 |
2.79 |
0.130 |
|
|
|
|
9th floor ceiling,
east |
|
|
|
|
|
12 |
EpiSen |
90 |
39.5 |
-3.76 |
10.8 |
5.98 |
0.210 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|